Recirculating Air Conditioning Unit
ACS-100
Model of an air conditioning system with outer air and recirculating operation. Air duct with transparent front. Air duct with fan, air cooler, humidifier, flaps, air heater and sensors. Chamber with wet (latent) and dry (sensitive) heat source as cooling load
Motorized flaps for recirculating and outer air operation. Process schematic with signal lamps. Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
Specifications
- Model of an air conditioning system with outer air and recirculating operation
- Air duct with transparent front
- Air duct with fan, air cooler, humidifier, flaps, air heater and sensors
- Chamber with wet (latent) and dry (sensitive) heat source as cooling load
- Motorized flaps for recirculating and outer air operation
- Process schematic with signal lamps
- Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
- Refrigerant R134a
- Comprehensive air conditioning teaching system, complete with initial heating stage, humidifier,
- Chiller/dehumidifier, final heating stage, climatic chamber with window, return duct and adjustable recirculation.
- Transparent duct for full visibility of the process and the components-.
- Fully instrumented, with temperature and relative humidity sensors at every stage of the process, plus an air
- Flow sensor-RH sensors calibrated for maximum accuracy-For academic analysis of the thermodynamic principles
- Fully computer controlled with real-time data logging of data and results and manual data recording
- Capability of heating, humidifying and reheat.
- Chamber-Adjustable recirculation of air leaving the chamber back into the conditioning duct.
- Data logger with user friendly software and USB download.
Technical data
- Model of an air conditioning system with outer air and recirculating operation
- Air duct with transparent front
- Air duct with fan, air cooler, humidifier, flaps, air heater and sensors
- Chamber with wet (latent) and dry (sensitive) heat source as cooling load
- Motorized flaps for recirculating and outer air operation
- Process schematic with signal lamps
- Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
- Refrigerant R134a
- Compressor (air-cooled condensing unit)
- Cooling 1.8 kW
- Humidifier
- Boiler power: 2 kW to 3kW
- Air heater
- Heating variation: 4 kW
- 2 heaters in the chamber as cooling load
- Power output: 0…250W each, freely adjustable
- Flow cross-section of the air duct
- WxH: 155x155mm
Measuring ranges
- Temperature: 0…50°C
- Rel. humidity: 10…90%
- Power: 2x 0…300W (cooling load)
- Pressure: -1…9bar / -1…24bar (refrigerant)
- Flow rate: 1,5…23,5L/h (refrigerant)
- Air velocity: 0…2,5m/s
- Environmental chamber of volume 1,3 m3
- 230V, 50Hz, 1 phase