Recirculating Air Conditioning Unit

ACS-100

Model of an air conditioning system with outer air and recirculating operation. Air duct with transparent front. Air duct with fan, air cooler, humidifier, flaps, air heater and sensors. Chamber with wet (latent) and dry (sensitive) heat source as cooling load

Motorized flaps for recirculating and outer air operation. Process schematic with signal lamps. Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories

Specifications

  1. Model of an air conditioning system with outer air and recirculating operation
  2. Air duct with transparent front
  3. Air duct with fan, air cooler, humidifier, flaps, air heater and sensors
  4. Chamber with wet (latent) and dry (sensitive) heat source as cooling load
  5. Motorized flaps for recirculating and outer air operation
  6. Process schematic with signal lamps
  7. Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
  8. Refrigerant R134a
  9. Comprehensive air conditioning teaching system, complete with initial heating stage, humidifier,
  10. Chiller/dehumidifier, final heating stage, climatic chamber with window, return duct and adjustable recirculation.
  11. Transparent duct for full visibility of the process and the components-.
  12. Fully instrumented, with temperature and relative humidity sensors at every stage of the process, plus an air
  13. Flow sensor-RH sensors calibrated for maximum accuracy-For academic analysis of the thermodynamic principles
  14. Fully computer controlled with real-time data logging of data and results and manual data recording
  15. Capability of heating, humidifying and reheat.
  16. Chamber-Adjustable recirculation of air leaving the chamber back into the conditioning duct.
  17. Data logger with user friendly software and USB download.

Technical data

  1. Model of an air conditioning system with outer air and recirculating operation
  2. Air duct with transparent front
  3. Air duct with fan, air cooler, humidifier, flaps, air heater and sensors
  4. Chamber with wet (latent) and dry (sensitive) heat source as cooling load
  5. Motorized flaps for recirculating and outer air operation
  6. Process schematic with signal lamps
  7. Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
  8. Refrigerant R134a
  9. Compressor (air-cooled condensing unit)
  10. Cooling 1.8 kW
  11. Humidifier
  12. Boiler power: 2 kW to 3kW
  13. Air heater
    • Heating variation: 4 kW
  14. 2 heaters in the chamber as cooling load
  15. Power output: 0…250W each, freely adjustable
  16. Flow cross-section of the air duct
  17. WxH: 155x155mm

Measuring ranges

  • Temperature: 0…50°C
  • Rel. humidity: 10…90%
  • Power: 2x 0…300W (cooling load)
  • Pressure: -1…9bar / -1…24bar (refrigerant)
  • Flow rate: 1,5…23,5L/h (refrigerant)
  • Air velocity: 0…2,5m/s
  • Environmental chamber of volume 1,3 m3
  • 230V, 50Hz, 1 phase