Efficiency in Heating Technology | ADF Didactic

Efficiency in Heating Technology

HS-105

The trainer contains a complete closed heating circuit with circulating pump, electrical heater, convector for dissipating heat, various pipe sections, fittings and safety devices. The losses of the most important fittings can be determined using seven differential pressure sensors.

Control response and energy flux can be plotted using four temperature sensors, a flow rate sensor and an effective power sensor. The characteristics of a conventional circulating pump and a differential pressure controlled circulating pump can be compared. The measured values are transmitted directly to a PC via Ethernet and can be processed with the supplied software. Both circulating pumps, the heater and the convector fan can be controlled via PC.

Specifications

  1. Fundamentals of energy efficient heating technology
  2. Closed water circuit with 2 circulating pumps, expansion vessel, heater and convector
  3. Two-point and PID software controller for temperature: reference variable, hysteresis and PID parameters adjustable
  4. Boiler safety group according to DIN 4751
  5. 7 differential pressure sensors, 4 temperature sensors, 1 effective power sensor and 1 flow rate sensor
  6. ADF software with control functions and data acquisition via Ethernet under Windows 8.1, 10

Technical Details

  1. Conventional circulating pump
  2. Power consumption: 140W
  3. Max. flow rate: 5m3/h
  4. Max. head: 7m
  5. Differential pressure-controlled circulating pump
  6. Power consumption: 4…50W
  7. Max. flow rate: 3,5m3/h
  8. Max. head: 6m
  9. Electric heater: 2000W
  10. Expansion vessel: 2L

Software controller:

  1. Adjustable reference variable: 0…80°C

Measuring ranges:

  • Differential pressure: 5x 0…600mbar, 2x 0…100mbar
  • Temperature: 0…100°C Flow rate: 0…50L/min
  • Effective power: 0…200W 230V, 50Hz, 1 phase

Required for operation

  • PC with Windows recommended