Computer Linked A/C Unit
CS-400
Air-cooling is provided by vapor compression refrigeration system with pressure, temperature and refrigerant flow measurement. It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.
The base unit comprises a variable speed radial acting axial flow fan discharging into a 250mm square duct with steam humidifier, electrical pre-heaters, direct expansion cooling coil/de-humidifier, electrical re-heaters and orifice plate for airflow measurement.
Specifications
- The Air Conditioning Laboratory Unit is designed to demonstrate the working principles of air conditioning system.
- All measurements a read manually and through computer linked software.
- Air-cooling is provided by vapor compression refrigeration system with pressure, temperature and refrigerant flow measurement.
- It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.
- The base unit comprises a variable speed radial acting axial flow fan discharging into a 250mm square duct with steam humidifier, electrical pre-heaters, direct expansion cooling coil/de-humidifier, electrical re-heaters and orifice plate for airflow measurement.
- It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.
- Instrumentation allows the electrical power to each resistive load to be measured and balanced against the air enthalpy change and mass flow.
- A complete instrumented air conditioning laboratory unit mounted on a frame and castor wheels.
- This unit consists of:
- Variable speed air blower Air humidifier
- Air pre-heater
- Air cooler/refrigerator
- Air re-heater
- Supplied with:
- Study of the end state properties of each air conditioning components Study of the vapor compression refrigeration system
- Determination of thermodynamic properties
Technical specifications:
- Psychrometric condition measured before and after each process by high precision wet and dry bulb sensors with 0 to
- Airflow is adjustable to at least 0.15 – 0.2 m3/s.
- Switchable heating up to 5 kW
- Switchable steam injection 5 kW electrical equivalent.
- Cooling is by a fully instrumented vapor compression cycle with nominally 2.5 kW capacity
Measuring ranges
- Temperature: 0…50°C
- Rel. humidity: 10…100 %
- Power consumption: 0…3000W (condensing unit)
- Power: 2x 0…2500W (cooling load)
- Pressure: -1…9bar / -1…24bar (refrigerant)
- Flow rate: 1,5…23,5L/h (refrigerant)
- Air velocity: 0…2,5m/s
- 230V, 50Hz, 1 phase