Computer Linked A/C Unit

CS-400

Air-cooling is provided by vapor compression refrigeration system with pressure, temperature and refrigerant flow measurement. It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.

The base unit comprises a variable speed radial acting axial flow fan discharging into a 250mm square duct with steam humidifier, electrical pre-heaters, direct expansion cooling coil/de-humidifier, electrical re-heaters and orifice plate for airflow measurement.

Specifications

  1. The Air Conditioning Laboratory Unit is designed to demonstrate the working principles of air conditioning system.
  2. All measurements a read manually and through computer linked software.
  3. Air-cooling is provided by vapor compression refrigeration system with pressure, temperature and refrigerant flow measurement.
  4. It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.
  5. The base unit comprises a variable speed radial acting axial flow fan discharging into a 250mm square duct with steam humidifier, electrical pre-heaters, direct expansion cooling coil/de-humidifier, electrical re-heaters and orifice plate for airflow measurement.
  6. It should allow the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer.
  7. Instrumentation allows the electrical power to each resistive load to be measured and balanced against the air enthalpy change and mass flow.
  8. A complete instrumented air conditioning laboratory unit mounted on a frame and castor wheels.
  9. This unit consists of:
    • Variable speed air blower Air humidifier
    • Air pre-heater
    • Air cooler/refrigerator
    • Air re-heater
  10. Supplied with:
    • Study of the end state properties of each air conditioning components Study of the vapor compression refrigeration system
    • Determination of thermodynamic properties 

Technical specifications:

  1. Psychrometric condition measured before and after each process by high precision wet and dry bulb sensors with 0 to
  2. Airflow is adjustable to at least 0.15 – 0.2 m3/s.
  3. Switchable heating up to 5 kW
  4. Switchable steam injection 5 kW electrical equivalent.
  5. Cooling is by a fully instrumented vapor compression cycle with nominally 2.5 kW capacity

Measuring ranges

  • Temperature: 0…50°C
  • Rel. humidity: 10…100 %
  • Power consumption: 0…3000W (condensing unit)
  • Power: 2x 0…2500W (cooling load)
  • Pressure: -1…9bar / -1…24bar (refrigerant)
  • Flow rate: 1,5…23,5L/h (refrigerant)
  • Air velocity: 0…2,5m/s
  • 230V, 50Hz, 1 phase