Two-stage biogas plant (continuous or discontinuous Tanks made of stainless steel operation possible)
2 stirred tank reactors made of stainless steel with capacities level sensors
Specifications
-
Two-stage biogas plant (continuous or discontinuous Tanks made of stainless steel operation possible)
-
2 stirred tank reactors made of stainless steel with capacities level sensors
-
Separate supply unit with substrate tank and feed pump
-
Control of temperature and pH value in the reactors
-
2 metering pumps for acid and caustic
-
Heating water circuit with tank, heater, temperature controller and pump
-
Biogas is dried with silica gel
-
Biogas analysis: flow rate, methane content, carbon dioxide content, humidity and temperature
-
Plant control with PLC via touch screen
-
Integrated router for operation and control via an end device and for screen mirroring: mirroring of the user interface on up to 5 end devices
-
Data acquisition via PLC on internal memory, access to stored measured values via WLAN with integrated router/ LAN connection to customer’s own network
Features
-
PLC: Eaton XV303
-
Tanks made of stainless steel
-
Reactor (stage 1): 26,3L
-
Reactor (stage 2): 73,5L
-
Substrate tank: approx. 30L
-
Digestate tank: 26,3L
-
-
Pumps
-
3 peristaltic pumps: each max. 25L/h
-
2 metering pumps: each max. 2,IL/h
-
Heating water pump: max. 480L/h
-
-
Stirring machines
-
Substrate tank: max. 200min -1
-
Reactors: each max. 120min -1
-
-
Measuring ranges
-
Methane content: 0…100%,
-
Carbon dioxide content: 0…100%
-
Flow rate: 0…30NL/h (biogas)
-
pH value: 2x 1…14
-
Humidity: 0…100%
-
Temperature: 3x 0…100°C (reactors and biogas)
-
Physical and Environmental
-
LxWxH: approx. 1100x790x1400mm (supply unit)
-
LxW×H: approx. 2060x790x1910mm (trainer)
-
LxW×H: approx. 1100×790x1400mm (post-fermentation unit)
- Weight :approx. 770 kg
Power and Electrical
- Mains Connection: 400V, 50Hz, 3 phases
-
Biomass from a biogas plant,
-
Substrate (recommendation: potatoes or maize),
-
Caustic soda,
-
Hydrochloric acid
-
Inert gas (e.g. carbon dioxide) Skg/h,
-
min. 2bar; water connection + drain 300L/h, min. 3bar;exhaust air + ventilation 245m°h